SPM32 principalis munus praebet ut infra
- Real-time notitia mensurae, verum RMS(Tres phase voltage, current, potentia activa, potentia reactiva, potentia apparentis, potentia factor, frequentatio, angulus phase).
- Imp. & Exp. Energy
- Calculum exige(Postulatio et culmen postulatum currentis, potentiae activae tres-phasis, potentia activa totalis)
- Terror munus
(terrorem super-voltage, sub-voltage, over-current, under-current, phase lost, over-frequency, under-frequency, over power, phase error, over-total power active demand, DI1 and DI2 status change)(Postulatio et culmen postulatum currentis, potentiae activae tres-phasis, potentia activa totalis) - Analysis harmonica: 2~63 intentionis harmonicae, 2~ 63th harmonicae currentis, THD(Postulatio et culmen postulatum currentis, potentiae activae tres-phasis, potentia activa totalis)
- Current unbalance, intentione unbalance, intentione zero - sequence component, Voltage positive - sequence component, Voltage negative - sequence component.
- Tribus - phase voltage angulus phase tres - phase angulus current.
- Ad libitum 2 digitalis input et 2 Nullam output
- Rated initus 1A vel 5A stabilis
- Ratum intentione: convenientiae 3x57.7/100V et 3x220/380V.
Specification
Mensuratio Parameter | Sagaciter | Mensuratio dolor |
Voltage | 0.2% | Recta input linea -line 10~500V, Linea neutra: 10~400V PT primaria:650KV, PT secundaria: 100-400V |
Current | 0.2% | CT primaria: 9,999A, CT secundaria: 5mA~6.5A |
Potentia factor | 0.5% | -1.0000~1.0000 |
Active virtus | 0.5% | 0~±9,999MW |
Reactivum potentiae | 1.0% | 0~±9.999Mvar |
Apparens potentia | 1.0% | 0~9,999MVA |
Active navitas | 0.5% | 0~99,999,999.9 kWh |
Reactivum industria | 2.0% | 0~99,999,999.9kVarh |
Apparens industria | 2.0% | 0-99,999,999.9kVAh |
Voltage aut current unbalance | 1.0% | 0%-100% |
Harmonic | classis B * | 0%~100% |
Mensuratio Parameter | Sagaciter | Mensuratio dolor |
Voltage | 0.2% | Recta input linea -line 10~500V, Linea neutra: 10~400V PT primaria:650KV, PT secundaria: 100-400V |
Current | 0.2% | CT primaria: 9,999A, CT secundaria: 5mA~6.5A |
Potentia factor | 0.5% | -1.0000~1.0000 |
Active virtus | 0.5% | 0~±9,999MW |
Reactivum potentiae | 1.0% | 0~±9.999Mvar |
Apparens potentia | 1.0% | 0~9,999MVA |
Active navitas | 0.5% | 0~99,999,999.9 kWh |
Reactivum industria | 2.0% | 0~99,999,999.9kVarh |
Apparens industria | 2.0% | 0-99,999,999.9kVAh |
Voltage aut current unbalance | 1.0% | 0%-100% |
Harmonic | classis B * | 0%~100% |