AC Din Rail-mounted Multi-Channel Multi-circuit Energy Meter SPM20 60A 220V for circuit monitoring system

1. Small Size - Can be installed at the closest point, integrate in existing space-constrained installations.

2. Ultra-compact Design - Consists of control unit and current sensors          (with RJ12 port, optional solid core or split core )

3. Wide Measurement Range - Max, Support 63A

4. Multi Circuit - Support 30 single phase circuit or 10 three phase circuit AC measuring

5. High Accuracy -Voltage & Current class 0.5 , kWh class 1.0

6. Multi Network Type - 1 phase 2 wires, 3 phase 4 wire

      Main Documents

      Compatible Software

      PiEMS System1vwd

      Smart PiEMS System

      Product Introduction

      Pilot SPM20-wxq
      • SPM20 is CE certificated for sub-metering, it suitable to Power distribution cabinet and switch cabinet of the Low-voltage distribution system less than AC 220V, and support to single phase two wires and three-phase four-wires system.

        Fully comply the following EMC Standard:
        IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-11,IEC62052-11 2003, and CISPR22:2006.

        Any metering combinations of: Single-Phase and Three-Phase are possible allowing users to provide flexibility with installations of electrical metering systems.Installation is achieved using Current Transformers (CT).
      Pilot SPM20-13tz
      • SPM20 CMS is a monitoring system especially to the power terminal by its micro distributed multi-circuit monitoring unit. It consists the measurement module and control module, and these two modules is connected by the PLbus general line which is also researched by Pilot, and the connector plug is by the standard RJ12 which can simplify the installation on site.
      SPM20wersh4
      • SPM20 widely be used in Hotel,Healthcare, Dormitory, Commercial Building, Office, Residential Building, and Reconstruction Project. One monitoring unit can support 30pcs measurement modules at most, and can monitor 10 three-phase circuits or 30 single phase circuits, and have the measurement and metering function to the general data of the three-phase branch (general power, total electric-energy). Its current measurement is in maximum 63A, can satisfy the different application on site.
      Pilot SPM202-xce
      • The micro distribution multi-circuit measurement unit can be for multiple installation, and the controller conforms to DIN35 rail install, and backboard screw fixation install; There are the closed in line installation and opening buckle mounting for the option as required. The connection between the measurement unit and controller is by the standard RJ12 port, can make the wiring arrangement easy on site.

        SPM20 provides the main function as below

      • 1.Realtime Measurement Voltage, Current, Active power , Reactive power, Apparent Power, Power Factor, Frequency
        2.Energy Consumption Active energy,Reactive energy
        3.Alarm Function Overload, Under load, Over current, Sensor fault 
        4.Communication 1 RS485 port, MODBUS-RTU protocol
      • wi7n

      Specification

      SPM20-M:Main Module

      Connection Mode

      1 phase 2wires,3 phase 4 wires

      Power Supply

      Self-supply,by A phase

      Voltage Input

      1 phase 2 wires 220V Range:40%-150%
      3 phase 4wires 3×220/380V Range;40%-1509%

      Frequency

      45~65Hz

      Power Loss

      Power supply circuits: 10W

      Communication

      RS485 serial,support Modbus-RTU Baudrate: 4800,9600,19200bps Address:1~247

      SPM20-C: Solid Core Sensor SPM20-O: Split Core Sensor
      Connection Mode Bus connection (2xRJ12 Port) Connection Mode Bus connection (2xRJ12Port)
      Rated Current Input 5(63)A Rated Current Input 10(50)A
      Installation Solid core Installation Split Core
      Open hole Φ8 mm Open hole Φ9.5 mm
      Sampling Rate 28k Hz Sampling Rate 28k Hz
       
      Parameter Accuracy Measuring Rang
      Voltage 0.5% 40%~120%
      Current Solid Core Sensor(C) 0.5% 0-63A,1%~120%
      Split Core Sensor(O) 1.0% 0-50A,1%~120%
      Power factor 1.0% -1~1
      Active power 1.0% Single phase:0~±14kW/var/VA Total:0~±42kWvar/VA
      Reactive power 2.0%
      Apparent power 2.0%
      Active energy Solid Core Sensor(C) 1.0% 0-99,999,999,9 kWh
      Split Core Sensor(O) 2.0% 0~99,999,999.9 kWh
      Reactive energy 2.0% 0~99,999,999.9 kVarh
      Frequency 0.01 45~65Hz
      Power frequency withstand voltage 2000VAC Environment Normal operating temperature:-20℃~+55℃ Operating temperature:-20℃~+50℃ Storage temperature:-30℃~+80℃ Humidity:<95%non-condensing
      Insulation resistance ≥100MΩ
      Impulse withstand voltage 6kV(peak)
      IP index P52(front pane)
      Standard  (EMC)
      Electrostatic discharge immunity test           IEC 61000-4-2,Level 4 Radiated radio-frequency electromagnetic field immunity (RFEMS)                                    IEC61000-4-3,Level4 Electrical fast transient test                    IEC61000-4-4,Level4 Surge immunity test (1,2/50μs~8/20μ)         IEC61000-4-5,Level4 Conduction disturbance rejection of radio frequency field induction
        Electromagnetic emission limits Voltage sag and short time interrupt immunity Power frequency withstand voltage IEC61000-4-6,Level 3 CISPR22:2006,Pass IEC61000-4-11,Pass IEC 62052-11 2003
      6579a8fycx6579a8f2el

      video

      Incorporate craftsmanship and responsibility into the products, Pilot Technology continues to promote the construction of standardized, automated and informational production lines to realize the digital intelligentize of production.
      Learn more from our product video review.