Pilot Business Level 3 DC EV Charger PEVC3302 240kW/360kW/480kW
Main Documents
Compatibility by Brand
-
With new electric car brands emerging all the time, it’s essential that modern charging stations are compatible with a wide range of models if electric cars are going to be the future.Pilot’s DC electric vehicle chargers support widely used charger connectors, including CCS1, CCS2 and CHAdeMO, from Tesla to Kia almost all electric car brands compatible with Pilot Charging Stations
Multi-directional Protection
- Multiple protection mechanisms, IP54 rating, dustproof and waterproof.
Smart Connectivity
- Seamless integration with smart systems for efficient communication and control. Optional RFID/App etc. for user identification and management.
Reliable software to boost your charging business
- The Sino’s Charging Management System supports charging fault cloud backup protection mechanism and orderly charging management algorithm, empowers you to get efficient monitoring and rich insights so you can manage your EV charging business with ease.
Customized for More Power
-
PEVC3302 series offer flexible configurations, software and standard connectors that can be used in any scenario such as EV bus stations, highway service stations, parking garages, commercial fleet operators, EV infrastructure operators and service providers, and EV dealer workshops.
- PEVC3302 series offer flexible configurations, software and standard connectors that can be used in any scenario such as EV bus stations, highway service stations, parking garages, commercial fleet operators, EV infrastructure operators and service providers, and EV dealer workshops.
SPECIFICATION
Power cabinet |
||
Parameter type Input parameters | Description | PEVC3302E/U-RCAB-480KW |
AC Power supply | 3P+N+PE | |
AC Voltage | 400VAC±10% | |
Frequency | 50/60Hz | |
THDi | ≤5% | |
Efficiency | ≥95%(load: 50%–100%) | |
Power factor | ≥0.99(load: 50%–100%) | |
Output parameters | Number of Output Ports | 8(max) |
Voltage | 150-1000VDC | |
Output power | 480kW | |
Voltage accuracy | ≤0.5% | |
Current accuracy | ≤1% | |
Environmental parameters | Operating temperature | –20°C~+50°C |
Storage temperature | –40°C~+75°C | |
Lightning protection | Level C | |
IP and IK rating | IP55/IK10 | |
Operating altitude | ≤2000m | |
Humidity | 5%–95% RH non-condensing | |
Safety protection | Insulation resistance | ≥10MΩ |
Impulse voltage | ≥2500VDC | |
Protection functions | Over current | √ |
Under voltage | √ | |
Over voltage | √ | |
Short circuit | √ | |
Emergency stop | √ | |
Over temperature protection | √ | |
Surge protection | √ | |
RCD | √ | |
Others | Cooling system | Forced air cooling |
Operational noise level | ≤65dB | |
Power distribution mode | Dynamic flexibility distribution | |
Interface protocol | CAN(alternative:RS485) | |
Enclosure type | Galvanized sheet steel | |
Dimensions (D x W x H) | 1600x850x2000mm | |
Weight | 700kg | |
Compliance | IEC61851-1,IEC61851-23,IEC61851-21-2 |
Power Cabinet |
|||
Input parameters | Description | PEVC3302E/U- SPOT-N1 | PEVC3302E/U- SPOT-D2 |
DC Voltage | 150-1000VDC | ||
AC Power supply | 1P+N | ||
AC Voltage | 230V(±10%) | ||
Frequency | 50/60Hz | ||
Output parameters | Number of Output Ports | 1 | 2 |
Connector | CCS1/CCS2 | ||
Voltage | 150-1000VDC | ||
Maximum current per channel | 250A | ||
Maximum power per channel | 250kW | ||
Voltage accuracy | ≤0.5% | ||
Current accuracy | ≤1.0% | ||
Environmental parameters | Operating temperature | –20°C~+50°C | |
Storage temperature | –40°C~+75°C | ||
Lightning protection | Level C | ||
IP and IK rating | IP55/IK10 | ||
Operating altitude | ≤2000m | ||
Humidity | 5%–95% RH non-condensing | ||
Protection functions | Over current | √ | |
Under voltage | √ | ||
Over voltage | √ | ||
Short circuit | √ | ||
Emergency stop | √ | ||
Over temperature protection | √ | ||
Surge protection | √ | ||
RCD | √ | ||
Insulation monitoring | √ | ||
Reverse polarity protection | √ | ||
Others | HMI | 7-inch touchscreen | |
Payment support | IC Card/APP | ||
Power meter | Accuracy Class 1.0 energy meter | ||
DC Cable length | 5m | ||
Operational noise level | ≤45dB | ||
Communication | Ethernet/4G | ||
Interface protocol | CAN(alternative:RS485) | ||
Enclosure type | Galvanized sheet steel | ||
Dimensions (D x W x H) | 450x200x1450mm | ||
Weight | 70kg | 85kg | |
Compliance | IEC61851-1,IEC61851-23,IEC61851-24,IEC62196-1,IEC62196-3 |
HPC Charge station | ||
Parameter type | Description | PEVC3302E/U-SPOT-N1 |
Input parameters | DC Voltage | 150-1000VDC |
AC Power supply | 1P+N | |
AC Voltage | 230V(±10%) | |
Frequency | 50/60Hz | |
Output parameters | Number of Output Ports | 1 |
Connector | CCS1/CCS2 | |
Voltage | 150-1000VDC | |
Maximum current | 500A | |
Maximum power | 480kW | |
Voltage accuracy | ≤0.5% | |
Current accuracy | ≤1.0% | |
Environmental parameters | Operating temperature | -20°℃~+50℃ |
Storage temperature | -40°℃~+75℃ | |
Lightning protection | Level C | |
IP and IK rating | P55/IK10 | |
Operating altitude | ≤2000m | |
Humidity | 5%-95%RH non-condensing | |
Protection functions | Over current | √ |
Others | Under voltage | √ |
Over voltage | √ | |
Short circuit | √ | |
Emergency stop | √ | |
Over temperature protection | √ | |
Surge protection | √ | |
RCD | √ | |
Insulation monitoring | √ | |
Reverse polarity protection | √ | |
HMI | 7-inch touchscreen | |
Payment support | IC Card/APP | |
Power meter | Accuracy Class 1.0 energy meter | |
DC Cable length | 5m | |
Operational noise level | ≤60dB | |
Communication | Ethernet/4G | |
Interface protocol | CAN(alternative:RS485) | |
Enclosure type | Galvanized sheet steel | |
Dimensions (D*W*H) | 450x400×1600mm | |
Weight | 120kg | |
Compliance | EC61851-1,IEC61851-23,IEC61851-24,IEC62196-1,IEC62196-3 |